100G QSFP28 Selection Guide: SR4 vs LR4 vs CWDM4 vs DWDM4

A practical selection guide for 100G QSFP28 optics: SR4 vs PSM4 vs CWDM4 vs LR4 vs DWDM4 compared by wavelength plan, fiber type, reach, FEC assumptions, and cost tier β€” with a decision flow for real deployments.

The short answer

Pick by distance and fiber plant first β€” wavelength plan, laser type, and cost follow from that decision:

ModuleWavelength planMediaReach*Typical roleCost tier
100G SR44 Γ— 25G VCSEL @ 850 nm, parallelOM3/OM4 MMF (MPO-12)70 / 100 mrack-adjacent, 4Γ—25G breakout$
100G PSM44 Γ— 25G @ 1310 nm, parallelSMF (MPO-12)500 mlow-cost SMF parallel$
100G CWDM44Ξ» CWDM 1271–1331 nm, duplex LCSMF2 kmdatacenter default (100 m–2 km)$$
100G LR44Ξ» LAN-WDM β‰ˆ 1296–1310 nm, duplex LCSMF10 kmcampus / metro edge / no-FEC plants$$$
100G DWDM44Ξ» DWDM, C-band 100 GHz ITU grid, duplex LCSMF10 kmcoexistence with DWDM line systems$$$$

*Reach figures assume RS-FEC enabled where the module spec requires it (CWDM4, PSM4). All five are 4 Γ— 25.78125 Gbps electrical lanes in the same QSFP28 cage β€” the differences are entirely optical.

Related transceiver specifications are catalogued on Canjintech's product pages

>SR4: shortest path, lowest cost per bit

SR4 uses four VCSEL pairs at 850 nm over parallel ribbon fiber β€” 8 fibers in an MPO-12 connector (4 TX + 4 RX).

CWDM4: the volume default β€” and why

CWDM4 packs four 25G lanes onto four coarse-WDM wavelengths (1271/1291/1311/1331 nm) over one duplex LC pair of single-mode fiber.

LR4: IEEE-grade margin for 10 km

100GBASE-LR4 (IEEE 802.3) uses the LAN-WDM grid β€” four wavelengths around 1296–1310 nm with tighter channel spacing and tighter laser tolerance than CWDM.

DWDM4: for plants that already speak DWDM

DWDM4 places its four lanes on the ITU-T 100 GHz DWDM grid in the C-band.

FEC and mixed-vendor realities

Module familyFEC assumptionInteroperability note
SR4 / PSM4PSM4 assumes RS-FEC; SR4 typically fine either wayBreakout partners must match (SR4 ↔ 25G SR)
CWDM4 / CLR4RS-FEC required by specCWDM4 ↔ CLR4 generally interoperate (same wavelengths)
LR4 / ER4Designed to run without FECSame wavelength plan across vendors; IEEE-defined
DWDM4FEC per system designBoth ends must use the same DWDM channel plan

Practical checks that prevent most field issues: confirm FEC is enabled on both switch ports, read DDM (Tx/Rx power, temperature) after link-up, and keep MPO/APC vs UPC polish consistent with the cassette plant.

Decision flow

flowchart TD
    A[100G link needed] --> B{Distance?}
    B -- under 100 m, MMF in place --> C[SR4]
    B -- 100 m to 2 km, SMF --> D[CWDM4]
    B -- 2 km to 10 km --> E{FEC available?}
    E -- yes --> F[CLR4 or LR4]
    E -- no --> G[LR4]
    B -- DWDM line system on path --> H[DWDM4]
    C --> I[Enable FEC + check MPO polarity]
    D --> I
    F --> I
    G --> I
    H --> I

Bottom line

Match both ends to the same module type, keep FEC on where the spec assumes it, and use DDM to catch plant problems before they become tickets.

Compiled from IEEE 802.3 specifications, CWDM4/PSM4 MSA public materials, and common operator practice; original synthesis, no reproduction.

FAQ

Can I replace CWDM4 with LR4 freely?
No. They use different wavelength plans (CWDM 1271–1331 nm vs LAN-WDM β‰ˆ1296–1310 nm). Two modules of the same type must be used on both ends of a link. Physically they share the duplex-LC SMF plant, but the optics will not link across types.
Does CWDM4 work without FEC?
The CWDM4 MSA spec assumes RS-FEC (KP4/KR4 FEC) is enabled. Most switches enable it by default for these rates, but if FEC is off, reach and margin degrade sharply. Verify FEC status in the switch before blaming the module.
Is SR4 compatible with 25G SFP28 ports?
Yes, via breakout: a 100G SR4 in a QSFP28 port breaks out to 4 Γ— 25G SFP28 SR over an MPO-to-4Γ—duplex-LC harness. This is the standard way to light 25G server ports from a 100G uplink.
How far does 100G run on OM4 multimode fiber?
100G SR4 reaches 100 m on OM4 (70 m on OM3). Beyond that, you need single-mode modules β€” CWDM4 is the usual next step, reaching 2 km over the same duplex LC patching style.